Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. PERMIT IS FOR UNIT #12 2. APPROVED PLANS SHOW NEW PIPING FOR UNITS #14-#19 3. CORRECTIONS MADE OK 4. UCC LEFT AT METER BY B.BENEDON |
|
| 06/27/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) UNITS 14-19. CORRECT ADDRESS ON PERMIT 2) SECURE VERTICAL PIPE AT WHS UNITS 14,19 3) PRESSURE TEST IS OK 4) PROVIDE 1" CLEARANCE FROM COMBUSTIBLE MATERIALS 5) CONNECT TO EXISTING GAS, SOAP TEST 6) RECALL FOR FINAL INSPECTION |