Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00966
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/15/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/14/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - CPVC THREADED FITTINGS SHALL BE ACCESSIBLE - USE THE PROPER TRANSITION FITTINGS AT WATER SERVICE, WCS AND LAVS - SUPPORT PIPING IN ATTIC AT 36" - KEEP PIPING OFF OF FLEXIBLE DUCT WORK. - 90 DEG. FITTINGS REQUIRE PROPER ALIGNMENT. - USE ANGLE STOPS DESIGNED FOR CPVC USE OR USE TRANSITION ADAPTORS. |