Permit: T06PL00926


Addresses:

10500 E DREXEL RD


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T06PL00926

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2007 SITE - SEWER Approved IVRS - Inspection :*
07/16/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
THIS INSPECTION FOR PHASE 3 AIR TESTING FOR
MANHOLE #29 TO CLEANOUT #2
LOTS #765-770 OK
MANHOLE #28 TO CLEANOUT #6
LOTS #801-806

PHASE 3 AIR TESTING COMPLETE
NEED OK FROM PIMA COUNTY & PCDEQ AUTHORIZATION TO DISCHARGE DOWNSTREAM FOR FINAL PHASE 3
06/27/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM MANHOLE #1 TO CLEANOUT #16
LOTS 516-521 AIR TEST OK
FROM MANHOLE #1 TO CLEANOUT #13
LOTS 512-515 AIR TEST OK
FROM MANHOLE #2 TO CLEANOUT #20
LOTS 522-527 AIR TEST OK
FROM MANHOLE #2 TO CLEANOUT #17
LOTS 508-511 AIR TEST OK
FROM MANHOLE #3 TO CLEANOUT #24
LOTS 528-533 AIR TEST OK
FROM MANHOLE #3 TO CLEANOUT #21
LOTS 506-509 AIR TEST OK

1. NEED OK FROM PIMA COUNTY & PCDEQ AUTHORIZATION TO DISCHARGE DOWNSTREAM FOR FINAL
04/02/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
6" SDR 35 SEWERS WITH 4" HCS LATERALS
FOR LADYSCIPPER LANE & TIGERLILY LANE FROM PUBLIC MANHOLES BEDDING, LAYING, TRACER OK
TO SHADE & BACKFILL
WILL TEST AT LATER DATE.
03/26/2007 SITE - SEWER Partial Approval IVRS - Inspection :*
1) FROM MANHOLE #6 TO CLEANOUT #12 & #9 PIPING TRACER WIRE AND BEDDING OK
2) FROM MANHOLE #5 TO CLEANOUT #8 & #5 PIPING TRACER WIRE AND BEDDING OK
3) FROM MANHOLE #4 TO CLEANOUT #4 & #1 PIPING TRACER WIRE AND BEDDING OK
4) FROM MANHOLE #3 TO CLEANOUT #12 & #24 PIPING TRACER WIRE AND BEDDING OK
5) VACUUM TEST TO BE DONE AT LATER DATE
03/13/2007 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
ADD 03045 SITE SEWER PRE-CONSTRUCTION MEETING WITH LEO, BORDERLAND
INSTALLATION SHALL REQUIRE DIRECTIONAL DRAINAGE FITTINGS, TRACER WIRE PER STATE STATUE 2256, BEDDING, SHADING WITH VISUAL INSPECTION PRIOR TO BACKFILL
AIR TESTING AT LATER DATE FOR PIPING WITH VERIFICATION OF GRADE BY ENGINEERING FIRM OR SURVEYOR.