Permit: T06PL00913

Parcel: 123130550


Addresses:

2225 N HAMPTON ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00913

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/21/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
14 PSI TEST IS OK.
LEFT GAS CARD.
CORRECTIONS HAVE BEEN MADE.
06/16/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
13 PSI TEST
REMOVE TEE FROM GAS LINE IN FURNACE CLOSET.
USE 4" VENT PIPE ON FURNACE.
TERMINATE 2' ABOVE EVAP. COOLER W/AN APPROVED CAP.
EXTEND WATER HEATER VENT 2" ABOVE EVAP. COOLER
PROVIDE T&P DRAIN ON WATER HEATER TO WITHIN 24" OF GROUND. RETEST SYSTEM.