Permit: T06PL00907

Parcel: 133261170


Addresses:

8136 E BAKER DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
06/09/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11.5 PSI
- GAS PRESSURE TEST IS OK
- PRIMER AND WRAP ALL TOOL MARKS ON PIPING BELOW GRADE AND TO A POINT 6" ABOVE GRADE.
- SECURE VENT CONNECTOR AT WH W/GALV SHEET METAL SCREWS AT EACH JOINT.
- BOND GAS PIPING TO ELECTRICAL PANEL OR TO METALLIC WATER PIPING.
- PROTECT EXTERIOR CPVC RELIEF DRAIN W/10 MIL. TAPE.
- FERROUS METALS ARE NOT TO BE CONNECTED TO NON-FERROUS METALS. BRASS SHOULD BE USED FOR EXTERIOR PRV VALVE.
- PRV TERMINATION SHALL BE 6" ABOVE GRADE.
- A PETITION OF APPEAL IS REQUIRED FOR A WATER HEATER W/T&P DRAIN INSIDE HOME. THIS CAN BE OBTAINED AT PERMIT COUNTER.