Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/06/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
OK FOR GAS
889-1888 SW GAS
T&P DRAIN DRIPPING
06/02/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. VENTS FROM WATER HEATER & FURNACE TO BE 2' ABOVE TOP OF COOLER INTAKE WHEN WITHIN 10' OF COOLER INTAKE WITH DOUBLE WALL VENT & CAP.
2. WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING SHALL GRAVITY DRAIN TO DAYLIGHT AND TERMINATE 6" TO 24" FROM FINISH GRADE AT 90 DEGREES DOWN.
3. PROVIDE BONDING OF BUILDING GAS PIPING.