Permit: T06PL00883

Parcel: 119210630

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/31/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
05/30/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
CORRET WH VENT
USE 3X4 REDUCER TO TRANSITION FROM 3" TO 4"
SECURE W/SCREWS NOT TAPE
PROVIDE 1' CLEARANCE FROM COMBUSTIBLES.
PROVIDE VENT CAP
TERMINATE 1' ABOVE ROOF
AGA VALVES REQUIRED
REPLACE APPLIANCE CONNECTORS (FLEXES)
SUPPORT PIPING AT WH
PROVIDE ELECTRICAL BONDING
REPLACE DRIPPING T&P VALVE
CORRECT FLUE VENT,
SINGLE WALL CANNOT PASS THROUGH CEILING
PROVIDE DOUBLE WALL B VENT THROUGH CEILING & ROOF
SECURE PIPING AT SECOND FURNACE.