Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/31/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 05/30/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* CORRET WH VENT USE 3X4 REDUCER TO TRANSITION FROM 3" TO 4" SECURE W/SCREWS NOT TAPE PROVIDE 1' CLEARANCE FROM COMBUSTIBLES. PROVIDE VENT CAP TERMINATE 1' ABOVE ROOF AGA VALVES REQUIRED REPLACE APPLIANCE CONNECTORS (FLEXES) SUPPORT PIPING AT WH PROVIDE ELECTRICAL BONDING REPLACE DRIPPING T&P VALVE CORRECT FLUE VENT, SINGLE WALL CANNOT PASS THROUGH CEILING PROVIDE DOUBLE WALL B VENT THROUGH CEILING & ROOF SECURE PIPING AT SECOND FURNACE. |