Permit: T06PL00839

Parcel: 120086140


Addresses:

161 W KENTUCKY ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/09/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
06/09/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PRESSURE TEST OK ON GAS
PROVIDE SEDIMENT TRAP AT WATER HEATER
INSTALL AGA VALVE AT STOVE WITH FLEX
INSTALL PIPE COVERING ON OUTSIDE PIPES
06/02/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
05/22/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PRESSURE TEST REQUIRED. USE 15 PSI GAUGE.
IF WATER HEATER IS GOING TO BE REPLACED -ADD TO PERMIT
TYPE B VENT REQUIRED.
T&P SHALL TERMINATE 6"-24" ABOVE GROUND.
FLUE VENTS WITHIN 10' OF COOLER SHALL BE EXTENDED TO 3' ABOVE COOLER.
AGA VALVES REQUIRED
ELECTRICAL BONDING REQUIRED.