Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/23/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 2000 N. PROVIDE TEST ON ENTIRE SYSTEM T&P SHALL GRAVITY DRAIN TO EXTERIOR OR OBTAIN VARIANCE (PETITION OF APPEAL). FLUE VENT SHALL BE DOUBLE WALL. |
|
| 05/19/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 12" OF COVER REQUIRED ON BELOW GRADE PIPING. TOOL MARKS AGA VALVES WH T&P SHALL TERMINATE OUTSIDE VERTICALLY, WITHOUT THREADS, USE APPROVED MATERIALS. DO NOT TRAP. WH/FUR VENT SHALL TERMINATE 3' ABOVE SWAMP COOLER USE DOUBLE WALL B VENT W/APPROVED CAP. RETEST, RECALL FOR INSPECT. |