Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 12 PSI TEST NEW PIPING OVERHEAD TO WATER HEATER, WALL HEATER, STOVE, FURNACE & DRYER OK GAS CARD AT METER |
|
| 05/18/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PIPING TO DRYER ABOVE IN CEILING TO BE SUPPORTED CORRECTLY. 2. VENT FROM FURNACE TO BE DOUBLE WALL THRU CEILING AND ROOF WITH APPROVED VENT CAP MINIMUM 2' ABOVE ANY AIR INTAKES INTO BUILDING. SINGLE WALL VENT REQUIRES 6" WALL VENT REQUIRES 1" CLEARANCE FROM COMBUSTIBLES AT WALL HEATER & WATER HEATER. 3. WATER HEATER T&P DRAIN SHALL GRAVITY DRAIN TO DAYLIGHT. |