Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/25/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 05/23/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* PET. #2006-080 INSTALL CORRECT LENGTH VENT CONNECTOR AND SECURE WITH A MIN. 2 SCREWS AT EACH JOINT. AFTER MAKING CORRECTION YOU MAY CALL SW GAS TO SCHEDULE SERVICE OK FOR GAS CALL 889-1888 RECALL FOR INSPECTION. |
|
| 05/22/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE PETITION OF APPEAL FOR T&P DRAIN. PLUG DRAIN PAN OUTLET TERMINATE 12 PSI RELIEF VALVE W/OUT THREADS. SECURE WH FLUE VENT W/GALV SHEETMETAL SCREWS. USE CORRECT SIZE CLAMPS AND SUPPORTS. PROVIDE A 15 PSI GAUGE W/1/10 PSI INCREMENTATION IN ORDER TO VERIFY LINE TIGHTNESS WITHIN A REASONABLE PERIOD OF TIME. |
|
| 05/19/2006 | PLUMBING - FINAL | Cancelled | IVRS - RI canceled |