Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/17/2006 | PLUMBING - FINAL | Approved | 1. CORRECTIONS MADE OK OK FOR GAS UCC LEFT AT METER |
|
| 05/16/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. ALL VALVES TO BE AGA OR CSA APPROVED 2. WATER HEATER "BOOT LEGGED" WILL REQUIRE CORRECTIONS VENT T&P |
|
| 05/16/2006 | PLUMBING - FINAL | Approved | 1. SECURE GAS PIPING AT STOVE AND EXTERIOR UP WALL AND IN ATTIC SPACE. 2. PROVIDE CORRECT INSTALLATINO OF WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING. IT SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION. NOTE: SHALL BE NO FLEX ON T&P PIPING. 3. PROVIDE UPPER COMBUSTION AIR FOR WATER HEATER MINIMUM 100 SQ. INCHES AT UPPER 12" OF WATER HEATER CLOSET. 4. PROVIDE CORRECT VENT THRU ROOF FOR WATER HEATER. THE TRANSITION IN ATTIC SPACE IS NOT CORRECT. |
|
| 05/15/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 05/10/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SEE 1211.1.2 2003 UPC -- COVER REQUIREMENTS 2. MAKE ALL CONNECTIONS TEST ENTIRE SYSTEM REATTACH BOND DID NOT ENTER RESIDENCE. |