Permit: T06PL00764

Parcel: 10820009A


Addresses:

826 E LIMBERLOST DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/17/2006 PLUMBING - FINAL Approved 1. CORRECTIONS MADE OK
OK FOR GAS
UCC LEFT AT METER
05/16/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. ALL VALVES TO BE AGA OR CSA APPROVED
2. WATER HEATER "BOOT LEGGED" WILL REQUIRE CORRECTIONS
VENT
T&P
05/16/2006 PLUMBING - FINAL Approved 1. SECURE GAS PIPING AT STOVE AND EXTERIOR UP WALL AND IN ATTIC SPACE.
2. PROVIDE CORRECT INSTALLATINO OF WATER HEATER TEMPERATURE & PRESSURE RELIEF DRAIN PIPING. IT SHALL GRAVITY DRAIN TO DAYLIGHT OR PROVIDE CITY SIGNED PETITION OF APPEAL ON SITE WITH CORRECT INSTALLATION.
NOTE: SHALL BE NO FLEX ON T&P PIPING.
3. PROVIDE UPPER COMBUSTION AIR FOR WATER HEATER MINIMUM 100 SQ. INCHES AT UPPER 12" OF WATER HEATER CLOSET.
4. PROVIDE CORRECT VENT THRU ROOF FOR WATER HEATER. THE TRANSITION IN ATTIC SPACE IS NOT CORRECT.
05/15/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
05/10/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. SEE 1211.1.2 2003 UPC -- COVER REQUIREMENTS
2. MAKE ALL CONNECTIONS
TEST ENTIRE SYSTEM
REATTACH BOND
DID NOT ENTER RESIDENCE.