Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL00734

Parcel: 112040980


Addresses:

2937 N FORGEUS AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/18/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1. GRAVITY DRAIN INSTALLED. CONTRACTOR TO INSTALL DIELECTRIC PROTECTION AT DISSIMILAR METALS.
2. OK FOR GAS
UCC LEFT AT METER
SW GAS 889-1888
09/14/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. FLEX CONNECTOR NOT APPROVED
HARD PIPE GRAVITY DRAIN.
06/02/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PROVIDE GRAVITY DRAIN TO DAYLIGHT FOR WATER HEATER TEMPERATURE & PRESSURE RELIEF OR OBTAIN PETITION OF APPEAL SIGNED BY CITY ON SITE WITH CORRECT INSTALLATION.