Permit: T06PL00722

Parcel: 135082230


Addresses:

7308 E EASTVIEW DR

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/12/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
06/15/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
36" X 1/4" ID APPLIANCE CONNECTOR APPEARS TO HAVE BEEN REUSED AND APPEARS TO BE UNDERSIZED.
1. REPLACE APPLIANCE CONNECTOR W/PROPERLY SIZED NEW CONNECTOR.
2. ONE JOINT ON VENT CONNECTOR IS NOT PROPERLY MADE, ALSO SECURE VENT CONNECTOR WITH 3 SCREWS AT EACH JOINT. TWO SCREWS DIRECTLY NEXT TO EACH OTHER DOES NOT PREVENT MOVEMENT IN EACH DIRECTION.
3. PROVIDE 1" OF CLEARANCE BETWEEN VENT AND WOOD CEILING.
4. WATER HEATER SUPPLY VALVE IS REQUIRED TO BE A FULL PORT VALVE.
5. EXTEND WATER HEATER VENT TO 3 FEET ABOVE SWAMP COOLER W/TYPE B VENT AND CAP.