Permit: T06PL00685

Parcel: 131032000

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/04/2006 PLUMBING - FINAL Approved
05/03/2006 PLUMBING - FINAL Not ready for Inspection 1. PROVIDE BONDING OF BUILDING GAS PIPING.
2. PROVIDE FULL SIZE 3/4" RIGID DRAIN TO DAYLIGHT FOR WATER HEATER TEMPERATURE & PRESSURE RELIEF DEVICE. THIS PIPING SHALL GRAVITY DRAIN TO DAYLIGHT & TERMINATE 90 DEGREE DOWN OR EXTERIOR 6" TO 24" FROM FINISH GRADE.
4. PROVIDE CORRECT SINGLE WALL VENT CONNECTOR BETWEEN WATER HEATER DRAFT HOOD AND ADJ. 90 DEGREE FITTING WITH 3-GALV SCREWS AT EACH JOINT OF VENT PIPING.
5. REMOVE TEMPORARY WEATHER COVER ON VENT TERMINATION AROUND VENT CAP.
6. RETEST SYSTEM.