Permit: T06PL00682

Parcel: 137030360

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00682

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
SEAL CLEANOUT PLUGS.
05/22/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
MAKE CONNECTION AT HOUSE.
BREAK SEPTIC TANK
BACKFILL
05/12/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
CALLED AT 9:11 A.M 955-0098 ARRIVED 9:49
PCWM PERMIT NOT NEEDED IF SADDLE IS USED.
TIE IN TO PUBLIC SEWER ABOVE FLOW LINE.
THERE IS NOT AN ELEVATION PLAN.
SEWER IS INSTALLED AT 1/4-3/8" PER FOOT SLOPE.
PROVIDE UNIFORM SLOPE OF 1/8" PER FOOT.
IT APPEARS THAT ADEQUATE FALL EXISTS.
AFTER CONNECTING TO PUBLIC SEWER INSTALL A TEST
WYE AS CLOSE AS POSSIBLE AND TESTES PRIVATE SEWER
2" BUILDING SEWER ON EAST SIDE OF HOUSE REQUIRES A CLEANOUT.
EXPOSED PIPNIG ON WALL SHALL BE METAL PIPE.
GALVANIZED PIPING IS NOT TO BE USED WITHIN 6" ON GROUND PROVIDE FLASHING. EXPOSE CONNECTION TO BUILDING DRAIN ON EAST SIDE.