Permit: T06PL00651

Parcel: 11805055A

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/25/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
04/21/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. TRACER WIRE REQUIRED ON BELOW GRADE PE
2. CLEAN SHADING AND FILL REQUIRED. NO CHUNKS LARGER THAN 3/4"
3. NO WOOD WITHIN 1" OF WH VENT.
4. T&P NOT OPERATING
5. NO TAPE AT TRANSITION OF VENT CONNECTOR TO VENT. SECURE WITH SHEET METAL SCREWS.
6. SECURE PIPING BEHIND STOVE.
7. SECURE PIPING AT FURNACE.