Permit: T06PL00637

Parcel: 133086220


Addresses:

8240 E ONEIDA PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/03/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
10/24/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MAKE UP VENT CORRECTLY AT DRAFT HOOD. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION DRAFT SPACE & PROVIDE 1/4" PER FOOT RISE ON VENT PIPING.
2. PROVIDE SEDIMENT TRAP AT GAS ENTRY FOR WATER HEATER & NEW SUPPLY FLEX PER WARNING LABEL PER MANUFACTURER.
3. PROVIDE 3-GALV SCREWS AT EACH JOINT OF FLUE VENT PIPING.