Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/03/2006 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 05/01/2006 | PLUMBING - INTERMEDIATE | Denied | EPOXY IS NOT AN APPROVED THREAD SEALANT. ALSO UPC REQUIRES THAT SHOWER VALVES BE ANTI-SCALD PRESSURE BALANCED. YOUR PLAN CALLS FOR FIXTURES TO BE REPLACED. | |
| 04/28/2006 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* WATER TEST WASTE & VENT THRU ROOF PER PLAN OK WATER PIPING OK 1. PROVIDE INSULATION ON EXTERIOR TO PROTECT FROM FREEZING. 2. PROVIDE CORRECT DRYER VENT. 3. SUPPORT SHOWER VALVES. |
|
| 04/18/2006 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE CORRECT SUPPORT FOR WATER PIPING. 2. PROVIDE CORRECT DRAINAGE FOR LAV AND WASHER BOX WITH CORRECT VENTING. 3. UNIONS ON WATER PIPING CANNOT BE IN UNACCESSIBLE LOCATION. 4. WATER HEATER TO BE INSTALLED ON APPROVED PAD, IN WEATHERPROOF ENCLOSURE, CORRECTLY. 5. EXPOSE ALL PIPING. 6. PROVIDE WATER PIPING THAT IS NOT DAMAGED. 7. PROVIDE TESTING ON ALL PIPING. 8. PROVIDE CITY APPROVED PLAN FOR ADDITION OF WASHER DRAINAGE. 9. PROVIDE DIELECTRIC PROTECTION FOR SERVICE CONNECTION. |