Permit: T06PL00608

Parcel: 113095600

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
05/30/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. NO TEST ON SYSTEM.
2. MAKE ALL CORRECTIONS FROM 4/17/06
AND RECALL INSPECTION.
04/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
04/17/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PIPING SHALL BE SUPPORTED WITH WEATHER RESISTANT SUPPORTS.
2. SECURE PIPING AT WALL PENETRATION TO STOVE.
3. SEAL PENETRATION.
4. PROVIDE PROTECTIVE ENCLOSURE FOR WATER HEATER INSTALLED OUTSIDE.
5. SECURE VENT W/SHEET METAL SCREWS AND BRACKET AT EVE.
6. T&P SHALL TERMINATE 6" ABOVE GROUND.
7. REMOVE PLUGGED TEE ON ROOF USE 90 DEGREE