Permit: T06PL00576

Parcel: 122170080


Addresses:

3408 E BELLEVUE ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/21/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
04/11/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
WATER HEATER INSTALLED OUTSIDE SHALL REST ON A CONCRETE OR OTHER APPROVED BASE 3" ABOVE GRADE.
PROVIDE A WORKING T&P VALVE.
DOUBLE WALL B VENT REQUIRED WHEN EXPOSED.
1/2 PIPING TO ROOFTOP FURNACE IS UNDERSIZED, USE 3/4" TO FURNACE.
SUPPORT PIPING ON ROOF AT 8' AND AT CHANGE OF DIRECTION.
PRESSURE DROPPING, USE A GAUGE WITH 1/10 PSI INCREMENTATION.