Inspection History Details
Inspection Status: Denied
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/12/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE SEDIMENT TRAP AT GAS ENTRY TO APPLIANCE. 2. PROVIDE CITY SIGNED PETITION OF APPEAL FROM ON SITE WITH CORRECT INSTALLATION CAP DRAIN IN WATER HEATER PAN, PROVIDE 1" FROM TOP LIP OF PAN AIR GAP FOR T&P DRAIN LINE. PROVIDE NIPPLE IN 125# PRESSURE RELIEF WITH NO THREADS ON DISCHARGE END. MAKE VENT UP CORRECTLY FOR WATER HEATER. 3. REMOVE TAPE AT SINGLE TO DOUBLE WALL CONNECTION FOR VENT FROM WATER HEATER. PROVIDE 3-GALV SCREWS AT EACH JOINT OF VENT PIPING. |
|
| 06/07/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 10:58 NO ACCESS REINSPECTION WHEN AN ADULT WILL BE PRESENT TO PROVIDE ACCESS. |