Permit: T06PL00572

Parcel: 121092890


Addresses:

5000 E GRANT RD #24


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00572

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/28/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
06/09/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
A PORTION OF THE PARTICLE BOARD FLOOR THAT THIS WATER HEATER RESTS ON IS COLLAPSING DUE TO PREVIOUS WATER DAMAGE.
THE WH IS LEANING BECAUSE OF THIS
I AM CONCERNED W/THE FIRE HAZARD ASSOCIATED WITH MOVEMENT OF A WATER HEATER DUE TO COLLAPSE OF THE SUPPORTING BASE.
SEC. 510.7 UPC AND THE WARNING LABEL ON THE WH REQUIRES THAT A DRAIN PAN W/A DRAIN BE INSTALLED IF THE SUB-FLOOR COULD BE DAMAGED BY A LEAK.
REPAIR THE FLOOR, INSTALL A DRAIN PAN W/A DRAIN AND PROVIDE COMBUSTION AIR AND PROVIDE A SEDIMENT TRAP
SECURE VENT TO CONNECTOR W/SCREWS.