Permit: T06PL00553

Parcel: 118033860

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Permit Number - T06PL00553

Inspection Description - PLUMBING - GAS PRESSURE TEST

Inspection Status - Approved

Date Description Inspector Results Comments
04/11/2006 PLUMBING - GAS PRESSURE TEST Approved
04/05/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE PRESSURE TEST
PLATFORM DOES NOT APPEAR TO BE STURDY ENOUGH TO SUPPORT WH
SECURE VENT PIPING W/SHEET METAL SCREWS
T&P RELIEF SHALL TERMINATE OUTSIDE
PROVIDE ROOF FLASHING AT PENETRATIONS
PROVIDE GAS FLEXES RATED FOR APPLIANCES SERVED
WATER HEATER IS NEW
SECURE WATER PIPING