Permit: T06PL00540

Parcel: 120092050


Addresses:

4544 S 5TH AV #01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
04/07/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
CALL SW GAS 889-1888
04/04/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
UNIT A-1 MANAGER
PROVIDE A PRESSURE TEST ON PIPING. USE A GAGE WITH 1/10 PSI INCREMENTATIONS.
PROVIDE T&P DRAIN TO EXTERIOR OF HOME
ENSURE THAT T&P DRAIN IS OPERATING
DOUBLE WALL B VENT IS INSTALLED UPSIDE DOWN INSTALL CORRECTLY
PROVIDE 1" OF CLEARANCE BETWEEN VENT AND WOOD.
SECURE WH VENT WITH SHEET METAL SCREWS AT EVERY JOINT.