Permit: T06PL00513

Parcel: 106051680


Addresses:

819 W SIMMONS RD

Inspection Status: Approved

Inspection History: PLUMBING - SEWER HCS CONNECT

Date Description Inspector Results Comments
05/17/2006 PLUMBING - SEWER HCS CONNECT Approved IVRS - Inspection :*
- CORRECTIONS MADE OK.
- OK TO COVER SEWER.
- NEED TO SEE CLEAN OUT AFTER COMPLETION.
05/12/2006 PLUMBING - SEWER HCS CONNECT Not ready for Inspection IVRS - Inspection :*
1. NO CONNECTION DOWNSTREAM OF TEST COMBO VISIBLE.
2. UNABLE TO LOCATE PLAN OR PERMIT.
3. OWNER NEEDS TO BE AWARE THAT THE BLDG. DRAIN FOR THE FRONT HOUSE IS PVC ELECTRICAL CONDUIT!
4. REPAIR COUPLINGS ARE PERMITTED ONLY AT P.O.C TO EXISTING. NEW 4" ABS COUPLINGS TO BE SOLVENT WELD TYPE.
05/09/2006 PLUMBING - SEWER HCS CONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
WYE PATTERN FITTINGS ARE REQUIRED
1. FOR HORIZONTAL CHANGES OF DIRECTION AND FOR CLEANOUT IN DRIVEWAY.
2. DRAINAGE FITTINGS AND MATERIALS REQUIRED AT CONNECTION TO NORTHERN HOUSE. ALSO CHECK SLOPE AT THIS LOCATION.
3. CONNECTION TO PUBLIC SEWER TO BE INSPECTED.