Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* CORRECTIONS HAVE BEEN MADE LEFT GAS CARD |
|
| 05/10/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* 15 PSI TEST IS OK OK TO BACKFILL TRENCH PROVIDE PROPER SIZE T&P DRAIN TO DAYLIGHT SLOPE DOWNWARD UNIT #11 PROVIDE T&P DRAIN TO DAYLIGHT, SLOPE DOWNWARD. |
|
| 04/27/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAUGE READING 2 PSI THERE IS A LEAK USE SOAPY WATER TO CHECK FOR LEAKS. |
|
| 04/06/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* UNITS 10 & 11 HOLDING PRESSURE. LEFT GAS CARDS. RECALL FOR INSPECTION ON UNIT 12 |
|
| 04/04/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* UNIT 10 DO NOT USE A 100LB GAUGE. UNIT 11 GAUGE DOES NOT WORK PROPERLY. UNIT 12 NOT HOLDING PRESSURE. ALL TEST GAUGES SHOULD BE 1/60TH LB INCREMENTS (15 PSI GAUGE) EVERYTHING ELSE IS OK |
|
| 03/29/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES AT WATER HEATERS. PROVIDE MIN 3 SCREWS IN VENT CONNECTORS. PROVIDE A TEST ON ENTIRE GAS SYSTEMS. MUST USE APPROVED TAPE PRIMER PRIOR TO TAPING JOINGS & TOOL MARKS. VENT PIPE EXTENSIONS ON ROOF MUST BE DOUBLE WALL PIPE W/APPROVED CAPS. |
|
| 03/27/2006 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* GATE LOCKED (BOTH) NO ACCESS |