Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T06PL00472

Parcel: 134251610


Addresses:

1149 S MANN AV

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/30/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
PETITION OF APPEAL #2006-050 ON SITE.
CORRECTION MADE
GAS CARD AT METER
03/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE FACTORY COATED PIPING FOR ALL UNDERGROUND PIPING.
2. UNDERGROUND GAS PIPING TO BE ON FIRM BED.
NO BRIDGING.
3. PROVIDE PETITION OF APPEAL FORM FOR ALTERNATE FORM OF TEMPERATURE & PRESSURE RELIEF ON SITE SIGNED BY CITY, PLUG PAN DRAIN & TERMINATE T&P DRAIN LINE 1" ABOVE TOP LID OF PAN.