Permit: T06PL00451

Parcel: 14117007F


Addresses:

7545 S HOUGHTON RD


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T06PL00451

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
09/21/2006 SITE - SEWER Approved IVRS - Inspection :*
07/27/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
VACUUM TEST MANHOLE #1 OK
VACUUM TEST MANHOLE #2 OK
06/15/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
BILL W/KIC SERVICES AND COT VERIFIED PRESSURE TESTS.
PRIVATE MH #1 TO PUBLIC MH #3 TEST OK
PRIVATE MH #1 TO PRIVATE MH #2 TEST OK
BILL W/KIC WILL VERIFY LAST HCS CONNECTION.
PROVIDE TEST RESULTS.
04/19/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
CONTINUATINO OF 8" SDR 35 FROM REDLINED 8X4 HCS LATERAL FOR SOUTH END OF BUILDING TO WEST, 8" CONTINUOUS TO MANHOLE #2, 4" DIP FROM MANHOLE 2 TO SOUTH BLD FOR HCS LATERAL.
REDLINE OF ADDITIONAL HCS SHALL BE
REVISED & CITY APPROVED.
BEDDING, SHADING, LAYING, TRACER OK
PENDING NOTES FROM 4/18/06 INSPECTION.
04/18/2006 SITE - SEWER Partial Approval IVRS - Inspection :*
FROM PUBLIC MANHOLE #3 8" SDR 35 TO PRIVATE
MANHOLE #1 FROM MANHOLE #1 8" SDR 35 SOUTH APP. 250' INCLUDING (3) 4" HCS LATERALS, BEDDING, SHADING, LAYING, TRACER OK PENDING VERIFICATION OF GRADE, AIR TESTING OF PIPING, VACUUM TESTING OF MANHOLES AND AUTHORIZATION OT DISCHARGE FROM ADEQ AT LATER DATE.
04/13/2006 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
PROVIDE CITY APPROVAL ON YOUR ADEQ APPROVED PLAN.
04/11/2006 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE CITY APPROVED PLAN & PERMIT ON SITE.
2. PROVIDE ADEQ APPROVAL OF PLAN IF REQUIRED.