Permit: T06PL00445

Parcel: 133210140

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/24/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
LEFT GAS CARD
ALL CORRECTIONS HAVE BEEN MADE
03/22/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE PIPE PRIMER THEN TAPE AT ALL UNDERGROUND FITTINGS & TOOL MARK PER 3/16/06 INSPECTION.
2. PROVIDE PERMIT FOR WATER HEATER PER 5/16/06 INSPECTION.
3. PROVIDE PETITION OF APPEAL FORM ON SITE SIGNED BY CITY FOR ALTERNATE FORM OF TEMPERATURE PRESSURE RELIEF WITH CORRECT INSTALLATION.
4. PROVIDE UPPER COMBUSTION AIR PER #4 (3/16/06)
5. DO ITEM #6 FORM 3/16/06
03/16/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. VENT FROM WATER HEATER TO HAVE 3 GALV SCREWS AT EACH JOINT OF VENT CONNECTIONS, SHALL HAVE MINIMUM 1" CLEARANCE FROM ALL COMBUSTIBLES AND CORRECT TRANSITION FITTING.
2. WATER HEATER TEMPERATURE PRESSURE RELIEF DRAIN PIPING SHALL GRAVITY DRAIN TO DAYLIGHT.
3. CAP OLD GAS PIPING REMOVE IT
4. PROVIDE UPPER COMBUSTION AIR OF 100 SQ. INCHES FOR WATER HEATER.
5. VENT FROM WATER HEATER WHEN WITHIN 10' OF AIR INTAKE SHALL BE 3' ABOVE TOP OF AIR INTAKE WITH APPROVED FULL SIZE DOUBLE WALL VENT PIPING THRU ROOF TO POINT OF TERMINATION WITH APPROVED DOUBLE WALL VENT CAP.
6. PROVIDE PERMIT FOR NEW WATER HEATER