Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) TEST FROM METER ABOVE GROUND TO WATER HEATER/FURNACE ONLY OK 2) GAS CARD AT METER |
|
| 03/08/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE MINIMUM TEST PRESSURE ON ENTIRE GAS SYSTEM FOR MINIMUM TIME WITH NO PRESSURE LOSS. 2. SEAL PENETRATION INTO BUILDING. 3. SECURE GAS PIPING CORRECTLY BEHIND WASHER/DRYER AREA TO WALL. 4. VENTS FROM WATER HEATER & FURNACE TO HAVE 3-GALV SCREWS AT EACH JOINT AND BE MADE UP CORRECTLY. 5. PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVES FOR BOTH APPLIANCES. 6. SECURE GAS PIPING IN FURNACE/WATER HEATER CLOSET CORRECTLY 7. PROVIDE BONDING OF BUILDING GAS PIPING. |