Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00393
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/23/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 20 PSI TEST OK LEFT GAS CARD |
|
| 03/21/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* GAS FLEX TO FURNACE 3/8 I.D. NOT ADEQUATE. PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR. VENT ON WATER HEATER MUST BE MIN. 5' IN TOTAL HEIGHT SYSTEM NOT HOLDING PRESSURE. |
|
| 03/15/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. THIS INSPECTOR WILL NOT ENTER A RESIDENCE WITHOUT ESCORT. 2. IN KNOCKED NO RESPONSE. |