Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 03/09/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* OK FOR GAS 1. PROVIDE DOUBLE WALL B VENT ABOVE ROOF YOU CANNOT TRANSITION FROM DOUBLE WALL TO SINGLE WALL, YOU CANNOT HAVE SINGLE WALL EXPOSED. RECALL FOR FINAL INSPECTION -- 03090 |
|
| 03/07/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. PROVIDE A FLASHING AT ROOF PENETRATION 2. PROVIDE WEATHER RESISTANT BLOCKS TO SUPPORT PIPING ON ROOF. 3. EXTEND DOUBLE WALL B VENT UP THROUGH ROOF AND ABOVE PARAPET. 4. PROVIDE ELECTRICAL BONDING OF GAS LINE 5. TERMINATE T&P RELIEF DRAIN OUTSIDE 6" ABOVE GROUND WITHOUT THREADS, USE APPROVED MATERIALS. 6. SEAL WALL PENETRATIONS 7. SUPPORT HORIZONTAL PIPING ON WALL RETEST, RECALL FOR INSPECTION. |