Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T06PL00386

Parcel: 106020950

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00386

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/05/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
1. CORRECTIONS MADE OK
OK FOR GAS
UCC LEFT AT METER
SW GAS 889-1888
05/31/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- #29 IS LOCATED SOUTH OF LAUNDRY ROOM IN CENTER OF COMPLEX.
- GAS PRESSURE TEST SHALL INCLUDE MOBILE HOME.
- GAS PRESSURE GAUGE SHALL HAVE 1/10 PSI INCREMENTATIONS IN ORDER TO ENSURE LINE TIGHTNESS WITHIN A REASONABLE TIME PERIOD.
- PIPING SUPPORTS SHALL BE WEATHER RESISTANT RED WOOD, PRESSURE TREATED WOOD OR METAL.
- SUPPORTS SHALL SECURE PIPE FROM MOVING.
- ALL GAS APPLIANCES SHALL BE BROUGHT UP TO CODE AND INSPECTED.
- WATER HEATER BASE SHALL BE FIRM AND LEVEL.
- WATER HEATER INSTALLED ON A WOOD SUB-FLOOR SHALL HAVE A DRAIN PAN TO PREVENT DAMAGE TO SUB-FLOOR.
04/24/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
04/21/2006 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. I COUNT ONLY 28 SPACES AT THIS MOBILE HOME COURT UNABLE TO LOCATE SPACE 29
NO NAME OR CONTACT NUMBER LEFT WITH INSPECTION REQUEST.
03/06/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME. MUST HAVE ACCESS TO ALL GAS APPLIANCES.