Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00386
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/05/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK OK FOR GAS UCC LEFT AT METER SW GAS 889-1888 |
|
| 05/31/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - #29 IS LOCATED SOUTH OF LAUNDRY ROOM IN CENTER OF COMPLEX. - GAS PRESSURE TEST SHALL INCLUDE MOBILE HOME. - GAS PRESSURE GAUGE SHALL HAVE 1/10 PSI INCREMENTATIONS IN ORDER TO ENSURE LINE TIGHTNESS WITHIN A REASONABLE TIME PERIOD. - PIPING SUPPORTS SHALL BE WEATHER RESISTANT RED WOOD, PRESSURE TREATED WOOD OR METAL. - SUPPORTS SHALL SECURE PIPE FROM MOVING. - ALL GAS APPLIANCES SHALL BE BROUGHT UP TO CODE AND INSPECTED. - WATER HEATER BASE SHALL BE FIRM AND LEVEL. - WATER HEATER INSTALLED ON A WOOD SUB-FLOOR SHALL HAVE A DRAIN PAN TO PREVENT DAMAGE TO SUB-FLOOR. |
|
| 04/24/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 04/21/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. I COUNT ONLY 28 SPACES AT THIS MOBILE HOME COURT UNABLE TO LOCATE SPACE 29 NO NAME OR CONTACT NUMBER LEFT WITH INSPECTION REQUEST. |
|
| 03/06/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE SCHEDULE AN INSPECTION WHEN SOMEONE WILL BE HOME. MUST HAVE ACCESS TO ALL GAS APPLIANCES. |