6862 E 42ND ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00377

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/14/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
10 PSI TEST IS OK
LEFT GAS CARD
CORRECTIONS HAVE BEEN MADE
03/13/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE MINIMUM TEST AT TIME OF INSPECTION WITH TEST GAUGE THAT IS IN 1/1OTH POUND INCREMENTS.
2. PLASTIC GAS PIPING REQUIRES 18" MINIMUM COVER
3. PROVIDE AGA OR CSA APPROVED GAS VALVES AT ALL APPLIANCES AND AT SERVICE LOCATION IF VALUE IS DESIRED.
4. PROVIDE WEATHER SEAL AT ROOF FLASHINGS & MASTIC BLOCKING ON ROOF.
5. PROVIDE GOOD BOND ON COLD BONDING CLAMP (CLEAN OFF PAINT)
6. PROVIDE PERM CAPS ON OLD GAS PIPING
7. PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER/FURNACE FLUE VENT PIPE. REMOVE TAPE AT SINGLE TO DOUBLE WALL CONNECTION ON WATER HEATER FLUE VENT.
8. PROVIDE WORKING TEMPERATURE & PRESSURE RELIEF FOR WATER HEATER
9. VENTS WITHIN 10' OF COOLER INTAKE TO BE 3' ABOVE FOR WATER HEATER AND 2' ABOVE FOR FURNACE WHEN WITHIN 10'