Permit: T06PL00348

Parcel: 133400140

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/03/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
03/01/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE AGA OR CSA APPROVED GAS SHUT OFF VALVE AT FURNACE.
2. PROVIDE APPROVED COUPLINGS FOR PIPING ACROSS ROOF FROM ROOFTOP UNIT TO WATER HEATER.
3. SECURE GAS PIPING DROP AT WATER HEATER
4. PROVIDE BONDING OF BUILDING GAS PIPING
5. SUPPORT GAS PIPING FROM ROOFTOP UNIT TO WATER HEATER DROP ON ROOF.
6. REMOVE TAPE AT SINGLE TO DOUBLE WALL VENT CONNECTION FROM WATER HEATER, AND PROVIDE 3-GALV SCREWS AT EACH JOINT OF WATER HEATER VENT PIPING.
7. HAVE NEW WATER HEATER ADDED TO YOUR PERMIT