Permit: T06PL00347

Parcel: 133170630


Addresses:

350 N WILMOT RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T06PL00347

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/20/2006 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
07/05/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
VALVES AND TEE INSTALLED PER WATER KEYNOTE #11
SITE SEWER IS SHOWN ON REVISED PLAN OF 51806, THIS SITE SEWER WORK IS NOT PART OF THIS PERMIT.
PROJECT MAY REQUIRE PDEQ AND ADEQ INCREMENTS
PROVIDE APPROVED PLAN WITH PDEQ STRAP.
04/14/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
NOTES FROM 4/12/06 INVALID
PIPING AT NORTHEAST BUILDING FOR NEW 6" FIRE RISER IS INSTALLED AND REQUIRES REDLINE AND FUTURE REVISED APPROVED PLAN.
NOTE: TUCSON FIRE WILL WANT TO INSPECT THIS AREA.
THIS PIPING IS 3' FROM THE CONNECTION AND JUST PAST STREET. PIPING TRAVELS FROM TEE APP. 3' 45 DEGREES DOWN APP. 5' 45 DEGREES HORIZONTAL APP. 10 HEADING WEST, 90 DEG. NORTH TRAVELS 33' NORTH 90 DEG.WEST,
2' WEST 45 DEG. DOWN OFFSET 6' TRAVELDOWN FOR FUTURE SEWER. 18' WEST, 45 DEG. UP AND 45 DEG. HORIZONTAL CAPPED TO CONTINUE JUST OUT OF EXISTING ROADWAY.
PROVIDE REDLINE AND REVISED PLAN OF THIS. NOTIFIED GENERAL CONTRACTOR THIS IS ENGINEERED PLAN AND REQUIRES CITY APPROVED REVISION.
04/12/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
6" C-900 AT NORTH END OF BUILDING OFFSET DOWN TO AVOID SEWER PER PLAN AND 45 DEGREE UP JUST PAST STREET AREA TO WEST.
04/06/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
INSTALL OF PIPING PER DELTA 3 SERVING AS REDLINE ON SITE FROM NOTE 3 STATION 3 + 29.69 TO STATION 1 + 65.41
INCLUDING (2) NEW HYDRANTS.
1. NEED PRESSURE TEST PER 2003 TUCSON WATER STATUTES WITH CHLORINIZATION & BACTERIA REPORT PRIOR TO TIE INS.
04/03/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
APPROVED PLAN DATED 2/27/06 RWS ON SITE
BUILDING FOR REVISED DELTA 3 SERVING AS REDLINE ON SITE DATED 3/21/06 TO BE APPROVED.
1. PROVIDE CORRECT BUDDING & SHADING OF PIPING.
2. PLEASE CONTACT LORENZO HERNANDEZ AT 791-2665 BEFORE PROCEEDING WITH THIS PROJECT.
THIS PROJECT MAY REQUIRE TUCSON WATER INSPECTION.
03/27/2006 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
03/27/2006 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. MET WITH CONTRACTORS FOR PRE-CON MEETING DISCUSSED CITY REQUIREMENTS FOR INSPECTIONS.