Permit: T06PL00333

Parcel: 137050580


Addresses:

332 W LOUISIANA ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/16/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
02/27/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
OVERHEAD ROOF WILL PROVIDE ADEQUATE PROTECTION OF WATER HEATER SO AN ENCLOSURE WILL NOT BE REQUIRED YOU HAVE SINGLE WALL PIPING WITHIN 6" OF COMBUSTIBLES
1. EXTERIOR VENT PIPING IS REQUIRED TO BE DOUBLE WALL TO PREVENT CONDENSATION DAMAGE TO WH
2. TERMINATE T&P 6"-24" ABOVE GRADE W/APPROVED MATERIALS.