Permit: T06PL00318

Parcel: 132170470


Addresses:

1132 E OHIO ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
03/28/2006 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
03/07/2006 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection :*
- YARD PIPING IS OK
- CONNECT PIPING TO HOUSE AND PRESSURE TEST ENTIRE SYSTEM
- PROVIDE ELECTRICAL BONDING
- USE APPROVED MATERIAL FOR TEMP & PRESS RELIEF LINE
CPVC, COPPER OR GALV IS REQUIRED FOR HOT WATER
- REMOVE TAPE FROM TRANSITION FROM SINGLE WALL VENT TO DOUBLE WALL B VENT.
- PROVIDE 1" CLEARANCE BETWEEN FLUE AND WOOD.
02/27/2006 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection :
See detailed listing on site.| 999*
STOVE & FURNACE OK
BELOW GROUND GAS PIPING NEEDS TO BE "SCOTCHKOTE" USE GAS PRIMER ON ALL FITTINGS AND TOOL MARKS BELOW GRADE.
PROVIDE 12" OF COVER ABOVE YARD PIPING
TERMINATE T&P DRAIN OUTSIDE 6" ABOVE GROUND W/OUT THREADS. CPVC IS OK TO USE.
TERMINATE WH TYPE B VENT 12" ABOVE ROOF.
PROVIDE BONDING.