Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/28/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 03/07/2006 | PLUMBING - GAS PRESSURE TEST | Partial Approval | IVRS - Inspection :* - YARD PIPING IS OK - CONNECT PIPING TO HOUSE AND PRESSURE TEST ENTIRE SYSTEM - PROVIDE ELECTRICAL BONDING - USE APPROVED MATERIAL FOR TEMP & PRESS RELIEF LINE CPVC, COPPER OR GALV IS REQUIRED FOR HOT WATER - REMOVE TAPE FROM TRANSITION FROM SINGLE WALL VENT TO DOUBLE WALL B VENT. - PROVIDE 1" CLEARANCE BETWEEN FLUE AND WOOD. |
|
| 02/27/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* STOVE & FURNACE OK BELOW GROUND GAS PIPING NEEDS TO BE "SCOTCHKOTE" USE GAS PRIMER ON ALL FITTINGS AND TOOL MARKS BELOW GRADE. PROVIDE 12" OF COVER ABOVE YARD PIPING TERMINATE T&P DRAIN OUTSIDE 6" ABOVE GROUND W/OUT THREADS. CPVC IS OK TO USE. TERMINATE WH TYPE B VENT 12" ABOVE ROOF. PROVIDE BONDING. |