Permit: T06PL00299

Parcel: 131041880


Addresses:

4725 E 25TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
08/08/2006 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection :*
05/01/2006 PLUMBING - GAS PRESS TEST FNL Partial Approval IVRS - Inspection :*
DO NOT USE A UNION IN A CONCEALED LOCATION.
REMOVE THE UNION IN THE WALL & RETEST SYSTEM.
INSTALL GAS APPLIANCES.
PRESSURE TEST IS OK. YOU CAN FINISH BACKFILL IN TRENCH.
BIRD BLOCKS AT NORTH END WILL PROVIDE ADEQUATE COMBUSTION AIR FOR FURNACE & WATER HEATER.
IF YOU WANT TO LEAVE THE UNION IN, PROVIDE AN ACCESS DOOR.