Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/22/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 02/17/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* - EXISTING WATER LINE IS COVERED CANNOT TELL IF IT HAS BEEN REPLACED OR NOT - IF POTABLE WATER LINE HAS BEEN REPLACED THEN IT WILL NEED TO BE EXPOSED PRIOR TO INSPECTION. - INSTALLATION OF RP TO PROTECT POTABLE WATER FROM RECLAIMED, WILL NEED TO BE INSTALLED ON THE POTABLE SYSTEM. - A TUCSON WATER PERMIT AND BACKFLOW CERTIFICATION WILL NEED TO BE PROVIDED. - IRRIGATION PIPING DOES NOT NEED TO BE INSPECTED BY DSD BUT TUCSON WATER MAY NEED TO INSPECT SYSTEM. |