Permit: T06PL00264

Parcel: 138020190


Addresses:

742 W CALLE RAMONA

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/14/2006 PLUMBING - FINAL Approved IVRS - Inspection :*
OK FOR GAS CALL SW GAS @ 889-1888
CUT OF THREADS AT T&P TERMINATION
02/10/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
- PIPING IN GROUND OK TO COVER
- ROOF PENETRATION REQUIRES A FLASHING
- INSTALL TYPE B DOUBLE WALL VENT W/AN APPROVED CAP FOR WATER HEATER.
- TERMINATE T&P RELIEF DRAIN 6"-24" ABOVE GRADE
- PROVIDE ELECTRICAL BONDING OF GAS LINE (GROUND TO WATER)
- SUPPORT PIPING ON ROOF W/WEATHER RESISTANT BLOCKS AND SECURE W/2 HOLE CLAMPS.
- RECALL INSPECTION AFTER COMPLETING