Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/06/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* GAS CARD AT METER SW GAS 889-1888 |
|
| 03/03/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE NIPPLE WITH NO THREADS ON DISCHARGE END FOR #125 PRESSURE RELIEF DEVICE 2) SEE NOTE #5 AND COMPLY 3) PLEASE PROVIDE VACUUM BREAKER AT HOSE BIB |
|
| 03/01/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PETITION OF APPEAL #2006-033 ON SITE 1. SERVICE GAS PIPING AT METER 2. REMOVE FUTURE TEE AT METER LOCATION SEE NOTE #6 2/17/06 3. HAVE NEW WATER HEATER ADDED TO PERMIT 4. SEE NOTE #5 FROM 2/17/06 |
|
| 02/23/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 2:17 NO ACCESS AN ADULT SHALL BE PRESENT TO PROVIDE ACCESS AT NEXT INSPECTION. |
|
| 02/10/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. POST NEW ADDRESS FOR THIS PROPERTY 2. PROVIDE MINIMUM TEST AND ACCESS TO ENTIRE GAS SYSTEM THIS IS NOT A COMPLETE LIST |