Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :*CORRECTIONS MADE OK OK TO BACKFILL GAS CARD ALREADY ON AT METER |
|
| 02/09/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. PROVIDE PRIMER THEN TAPE ALL TOOL MARKS & FITTINGS |
|
| 02/06/2006 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* 1) EXTEND WATER HEATER FLUE PIPING ABOVE COOLER-SECURE WITH SCREWS 2) PROPERLY SUPPORT GAS PIPING ON ROOF AND AT WATER HEATER DO NOT STRAIN PIPING, MAINTAIN MINIMUM 1 1/2" CLEARANCE ABOVE ROOF PROVIDE BONDING 3) PROVIDE APPROVED MATERIALS FOR T & P 4) PROVIDE WORKING T & P VALVE WITH TERMINATION TO EXTERIOR |