Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* TEST FROM METER UNDERGROUND TO OVERHEAD TO EXISTING BUILDING ENTRY TO STOVE, WATER HEATER AND FURNACE OK --- GAS CARD AT METER |
|
| 02/07/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :*REQUIRE MINIMUM 12 INCHES OF COVER ALL PIPING IS TO BE EXPOSED ALL U.G FITTINGS TO BE TAPED WHERE IS THE BOND BETWEEN WATER AND GAS? |
|
| 02/07/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNDERGROUND GAS PIPING SHALL NOT BE INSTALLED UNDER BUIILDING OR STRUCTURE ( PORCH OVERHANG) WITHOUT CORRECT SLEEVING THAT WILL WITHSTAND PRESSURE TEST. PRIME & TAPE ALL TOOL MARKS ON UNDEGROUND PIPING PROVIDE 3- GALV SCREWS AT SINGLE TO DOUBLE WALL VENT CONNECTION IN WATER HEATER /FURNACE CLOSET AND EXTEND VENT TO 3' ABOVE TOP OF COOLER INTAKE WITH APPROVED FULL SIZE DOUBLE WALL VENT MATERIAL WHEN WITHIN 10' OF COOLER INTAKE |