Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/23/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK 2. OK FOR GAS 3. UCC LEFT AT METER SW GAS 889-1888 |
|
| 02/21/2006 | PLUMBING - FINAL | Not ready for Inspection | NO VENT ON WATER HEATER FLEX CONNECTOR MAY NOT PASS THRU WALL OR PARTITION REMOVE TEST TEE, AND TEST AT TEE AT METER USE CORREC GAUGE NO BOND ON PIPING OK TO COVER UNDERGROUND |
|
| 02/16/2006 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PROVIDE 1" MIN. CLEARANCE FROM COMBUSTABLES AT ROOF PENETRATION EXTENT DOUBLE WALL VENT TERMINATION TO 3' ABOVE FORCED AIR INLET ( COOLER) PROVIDE ELECTRICAL BONDING TRIM T & P TERMINATION TO 6" ABOVE GROUND |