Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/04/2007 | SITE - SEWER | Approved | IVRS - Inspection :* 4" BRANCH TO #16-#19 OK TO COVER CONTRACTOR TO REDLINE ROUTE ON PLAN |
|
| 04/27/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. ALL SECTIONS TESTED OK 2. NEED TO SEE FINAL CONNECTIONS |
|
| 04/20/2007 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* NOT READY FOR INSPECTION |
|
| 04/11/2007 | SITE - SEWER | Not ready for Inspection | PROVIDE INSPECTION HISTORY FOR SECTIONS NOT NOTED ON INSPECTION HISTORY | |
| 04/10/2007 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* | |
| 04/03/2007 | SITE - SEWER | Partial Approval | IVRS - Inspection :* REVIEWED W/KAREN SEWER |
|
| 04/02/2007 | SITE - SEWER | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLEASE PROVIDE INSPECTION HISTORY FOR THE TESTING OF THE PRIVATE SEWER. YOU HAVE NOT BEEN GIVEN PERMISSION TO CONNECT TO BLDGS. MUST HAVE PLAN AND PERMIT ON SITE FOR INSPECTION |
|
| 03/27/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. PLEASE BE ADVISED WHEN YOU SCHEDULE AN INSPECTION LIKE THIS ESPECIALLY ONE THAT YOU HAVE MADE AN APPOINTMENT FOR - PLEASE BE READY. THE INSPECTOR DOES NOT HAVE TIME TO STAND AROUND WHILE THE TESTERS SET ABOUT PREPARING FOR THE TEST. (THESE GUYS WERE PRETTY FAST). 2. CONTRACTOR SHOULD BE ON SITE. TECHNICALLY I CANNOT DO AN INSPECTION WITHOUT APPROVED PLAN AND PERMIT ON SITE. 3. MANHOLE #2 - 15 SECOND W/LESS THAN ONE POUND DROP. ACTUAL TEST 29 SEC. MANHOLE #3 - 15 SECONDS W/NO PERCEPTIBLE DROP ACTUAL TEST 29 SEC. |
|
| 03/08/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* TWO BASES POURED OK OK TO STACK MANHOLES |
|
| 03/03/2006 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 1. 8" SDR35 BETWEEN PUBLIC MH #1 AND PRIVATE MH #2 OK NOTE: 4" BRANCH IS NOT SHOWN ON THE PLAN. CONNECTION TO 8" MADE OK - DO NOT COVER 4" 8" SDR 35 BETWEEN MH #2 AND #3 OK WITH ONE LATERAL INCLUDED. 8" SDR BETWEEN MH #3 AND BCS #3 OK TO COVER SUBJECT TO VERIFICATION OF GRADE WATER TEST OK THESE SECTIONS NEED TO SEE BASES AFTER THEY ARE POURED. |