Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T06PL00154
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/16/2006 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/27/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED TO SEE CONNECTION TO EXISTING 2) NEED TO SEE DISHWASHER INSTALL |
|
02/24/2006 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. CORRECT SLOPE OF TRAP ARM ROLL VENT OFF AT 45 DEG. 2. "EACH VENT PIPE SHALL HAVE ITS INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE" - SEE SEC 905.2 UPC 3. PROVIDE PERM CAP FOR TEST WYE 4. WRAP ABS WHERE PENETRATING CONCRETE PERMISSION TO COVER WALL, EXCEPT FOR VENT TIE IN LOCATION |