Permit: T06PL00145

Parcel: 131130440

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
02/14/2006 PLUMBING - FINAL Approved IVRS - Inspection :*15 PSI TEST IS OK
ALL CORRECTIONS HAVE BEEN MADE
02/08/2006 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
15 PSI TEST IS OK ON PIPE IN TRENCH OK TO BACKFILL. FINISH GAS LINE ABOVE GROUND TO POOL HEATER. BE SURE TO USE PROPER SUPPORT. RETEST SYSTEM.
02/02/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PROVIDE TALLER RISER OR SCOTCH COATED PIPE WITH PRIMED & TAPED COUPLING ON RISER TO 6" ABOVE GRADE AT METER.
2. PROVIDE TEST GAUGE IN 1/10 POUND INCREMENTS FOR TESTING.
3. AOBE GRADE PIPING SHALL NOT CREATE A TRIPPING HAZARD AT POOL HEATER LOCATION. PROVIDE FULL SIZE PIPING TO HEATER