Permit: T06PL00132

Parcel: 116275410

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T06PL00132

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/28/2006 PLUMBING - FINAL Approved IVRS - Inspection :*OK FOR GAS
02/16/2006 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*NO ANSWER AT DOOR
PROVIDE ACCESS TO GAGE
PROVIDE SCOTCH RISERS
USE PRIMER ON ALL FITTINGS AND TOOL MARKS THEN WRAP WITH 10 MILL TAPE
PROVIDE BTU OF GAS GRIL TO BE INSTALLED
REMOVE ROCKS LARGER THAN 3/4" FROM PIPING